126 research outputs found

    Considerable enhancement of the critical current in a superconducting film by magnetized magnetic strip

    Full text link
    We show that a magnetic strip on top of a superconducting strip magnetized in a specified direction may considerably enhance the critical current in the sample. At fixed magnetization of the magnet we observed diode effect - the value of the critical current depends on the direction of the transport current. We explain these effects by a influence of the nonuniform magnetic field induced by the magnet on the current distribution in the superconducting strip. The experiment on a hybrid Nb/Co structure confirmed the predicted variation of the critical current with a changing value of magnetization and direction of the transport current.Comment: 6 pages, 7 figure

    Dose mapping of a gamma industrial radiation facility using a practical and computational dosimetry

    Get PDF
    Comparison results for absorbed dose mapping of the Co60 industrial radiation facility BULGAMMA of Sopharma PLC, Bulgaria using a practical and computational dosimetry are presented in the paper. The gamma radiation facility is based on JS-8500 Co60 irradiator produced by MDS Nordian, Canada. The absorbed dose distributions of gamma rays in an irradiated product on JS-8500 Co60 irradiator have been calculated using the ModeGR Monte Carlo software. The software ModeGR was designed specially for simulation of the absorbed dose distribution within multi-layer packages irradiated with gamma ray from flat panoramic Co60 source rack using a Monte Carlo method. Absorbed dose measurements into containers filled with material using Ethanol Chlorobenzene chemical dosimeters were carried out to validate the software ModeGR. The comparison results show that software ModeGR can be used as a predictive tool for detailed dose mapping in gamma irradiated product. В работе рассматривается сравнение результатов картографирования поглощенной дозы гамма излучения Co60 на промышленном радиационном оборудовании БУЛГАММА, Софарма, София, Болгария с использованием практической и компьютерной дозиметрии. Гамма радиационное оборудование основано на излучателе JS-8500 Co60 производства фирмы MDS Nordian, Canada. Расчет распределение поглощенной дозы гамма излучения в облучаемой продукции на JS-8500 Co60 излучателе проводилось методом Монте Карло программой ModeGR. Программа ModeGR была специально разработана для моделирования распределение поглощенной дозы в многослойных мишенях, облучаемых гамма излучением на плоском панорамном излучателе Co60. Измерение поглощенной дозы гамма излучения в контейнерах, заполненных материалом, проводилось химическими дозиметрами Ethanol Chlorobenzene для валидации программы ModeGR. Результаты сравнения экспериментальных и расчетных данных показали, что программа ModeGR может использоваться как инструментарий для предсказания детальной карты поглощенной дозы в гамма облученной продукции. У роботі розглядається порівняння результатів картографування поглиненої дози гама випромінювання Co60 на промисловому радіаційному обладнанні БУЛГАММА, Софарма, Софія, Болгарія з використанням практичної й комп'ютерної дозиметрії. Гама радіаційне обладнання базується на випромінювачі JS-8500 Co60 виробництва фірми MDS Nordіan, Canada. Розрахунок розподілу поглиненої дози гама випромінювання в продукції, що опромінюється на JS-8500 Co60 випромінювачі, проводився методом Монте Карло програмою ModeGR. Програма ModeGR була спеціально розроблена для моделювання розподілу поглиненої дози в багатошарових мішенях, що опромінюються гама випромінюванням на плоскому панорамному випромінювачі Co60. Вимірювання поглиненої дози гама випромінювання в контейнерах, заповнених матеріалом, проводилося хімічними дозиметрами Ethanol Chlorobenzene для валідації програми ModeGR. Результати порівняння експериментальних і розрахункових даних показали, що програма ModeGR може використовуватися як інструментарій для прогнозування детальної карти поглиненої дози в гама опроміненої продукції

    MODELING THE BURNUP PROCESS OF NPN AND PUO2 FUEL COMPOSITIONS IN THE ADVANCED CONCEPTS OF A PULSED BATCH REACTOR IBR-3 AND IBR-4

    Full text link
    The work is devoted to software modeling of the burnup process of NpN fuel composition in the concept of a pulsed batch reactor IBR-3 and PuO2 fuel in the concept of a pulsating reactor IBR-4 based on the parameters of heterogeneous multi-zone cells of the corresponding reactor cores

    Feasibility studies of the time-like proton electromagnetic form factor measurements with PANDA at FAIR

    Full text link
    The possibility of measuring the proton electromagnetic form factors in the time-like region at FAIR with the \PANDA detector is discussed. Detailed simulations on signal efficiency for the annihilation of pˉ+p\bar p +p into a lepton pair as well as for the most important background channels have been performed. It is shown that precision measurements of the differential cross section of the reaction pˉ+pe++e\bar p +p \to e^++ e^- can be obtained in a wide angular and kinematical range. The individual determination of the moduli of the electric and magnetic proton form factors will be possible up to a value of momentum transfer squared of q214q^2\simeq 14 (GeV/c)2^2. The total pˉ+pe++e\bar p +p\to e^++e^- cross section will be measured up to q228q^2\simeq 28 (GeV/c)2^2. The results obtained from simulated events are compared to the existing data. Sensitivity to the two photons exchange mechanism is also investigated.Comment: 12 pages, 4 tables, 8 figures Revised, added details on simulations, 4 tables, 9 figure

    Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

    Full text link
    This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski, Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy), Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy

    Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR

    Get PDF
    Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel pˉpe+e\bar p p \to e^+ e^- is studied on the basis of two different but consistent procedures. The suppression of the main background channel, i.e.\textit{i.e.} pˉpπ+π\bar p p \to \pi^+ \pi^-, is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance
    corecore